Byte 03, Bit 6 - TrmIOP
The value returned for this field is 0, which indicates that the CTS
does not support the Terminate I/O Process message.
Byte 03, Bits 3 through 0 - Response Data Format
The value returned for this field is 2h, which indicates that the data
found is in accordance with the ANSI SCSI-2 standard.
Byte 04 - Additional Length
The value returned for this field is 65h, which indicates that there are
65h (101) additional bytes of Inquiry data available to be returned to
the initiator.
Byte 05 and 06 - Reserved
These bytes are reserved.
Byte 07, Bit 7 - RelAdr
The value returned for this field is 0, which indicates that the CTS
does not support relative addressing.
Byte 07, Bit 6 - WBus32
The value returned for this field is 0, which indicates that the CTS
does not support 32-bit-wide bus transfers.
Byte 07, Bit 5 - WBus16
The value returned for this field is 0, which indicates that the CTS
does not support 16-bit-wide bus transfers.
Byte 07, Bit 4 - Sync
The value returned for this field is 1, which indicates that the CTS
supports synchronous data transfer.
Byte 07, Bit 3 - Linked
The value returned for this field is 0, which indicates that the CTS
does not support linked commands.
Byte 07, Bit 2 - RSVD
This bit is reserved.
Byte 07, Bit 1 - CmdQue
The value returned for this field is 0, which indicates that the CTS
does not support tag command queuing.
5-6
EXB-8205 and EXB-8505
(Standard and XL)
510503