Writing Data for Directory Support
To write data to make use of the directory support feature and the
READ POSITION and LOCATE commands, follow these steps:
1. At LBOT, create a directory pad by writing “filler” data (data
that you do not intend to store) to tape. This reserves an area of
tape for the master directory that will list the location of the data
sets on tape.
The directory pad can be up to 10 MBytes in length. It should be
big enough to store the following:
The names of all the data sets you plan to store on the tape
(plan for the maximum number of data sets and assume that
each data set will use the longest allowable name).
Four bytes of READ POSITION data for each data set on
tape.
Note: Forbestresults,use1KByte(orsmaller)
fixed-length blocks to create the directory pad.
Important
When writing this pad in 8500c format, disable data
compression by setting the DCE bit on the Data
Compression Page of the MODE SELECT command
to 0. This ensures that the pad area is the correct
length. After writing this pad and the pad described
in the following step, you can set the DCE bit back to 1
to enable compression.
LBOT
DIRECTORY PAD
May 1994 EXB-8205 and EXB-8505
(Standard and XL)