10.1 About These Commands
The MODE SELECT command allows the initiator to specify medium,
logical unit, and device parameters. The MODE SENSE command
enables the CTS to report these parameters to the initiator. These
values apply to all initiators in a multi-initiator environment.
MODE SELECT and MODE SENSE parameters can be structured in
either of two formats: non-page format or page format.
Non-Page Format
In non-page format, the parameters after the Block Descriptor are
vendor unique. This format is the same as that defined for the
EXB-8200 (SCSI-1 format). The parameters are transferred in the
following order:
Parameter List Header
Block Descriptor (optional)
One to five bytes of vendor-unique parameters
Page Format
In page format, the parameters after the Block Descriptor are
structured as pages of related parameters (SCSI-2 format). The
parameters are transferred in the following order:
Parameter List Header
Block Descriptor (optional)
One or more pages of related parameters
Reporting Compression Parameters with MODE SENSE
The data compression parameters that can be returned with the
MODE SENSE command depend on whether your SCSI driver uses
non-page format or page format:
In non-page format, the only compression-related information
thatcanbereturnedistheDensityCode,whichislocatedinthe
Block Descriptor (see Section 10.6).
In page format, the compression-related information that can be
returned includes the Density Code in the Block Descriptor, the
Data Compression Page, and the Data Compression Status Page.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
10-3
10 MODE SELECT (15h) andMODE SENSE (1Ah)