EOD Detected
If the CTS detects the EOD mark (or blank tape for 8200 format)
during the read operation, it returns Check Condition status. The
REQUEST SENSE data is set as follows:
Valid 1
Sense Key Blank Check (8h)
Information
bytes
Depend on the setting of the Fixed bit, as follows:
If the Fixed bit is 0, equal the requested transfer length
If the Fixed bit is 1, equal the difference between the
requested transfer length and the actual number of
logical blocks read.
ASC 00h
ASCQ 05h
FSC 0Ch
When the READ command terminates, the logical position is after the
last recorded data block, filemark, or setmark (8500c format only).