21.2 Field Definitions
Byte 01, Bit 4 - PF (Page Format)
The Page Format bit specifies the format of the parameter list for the
SEND DIAGNOSTIC command. The CTS does not support any
pages, so the valid value for this field is 0.
Byte 01, Bits 2 through 0 - SelfTest, DevOfL, UntOfL
The SelfTest, DevOfL (Device Offline), and UntOfL (Unit Offline) bits
are used together to determine the test to be performed and the data
to be returned to the initiator. Refer to Table 21-1 for the valid
combinations of these three bits.
Bytes 03 and 04 - Parameter List Length
The Parameter List Length field is used only when the MD bit (byte
05,
bit 7) is 1. If the MD bit is 0, the Parameter List Length field must be
set to 0000.
As shown in Table 21-1, if the MD bit is 1 and the SelfTest, DevOfL,
and UntOfL bits are set to 000, the Parameter List Length field
specifies the starting address for the memory dump. Valid values for
the memory dump starting address are 0000h to 97FFh.
Byte 05, Bit 7 - MD (Memory Dump)
This bit indicates if a processor memory dump is requested, as
follows:
0 – Memory dump not requested.
1 – Memory dump requested.
If the MD bit is 1, the SelfTest, DevOfL, and UntOfL bits must be 000.
Note: If the MD bit is 1 and the SelfTest, DevOfL, and UntOfL bits
are not 000, the SEND DIAGNOSTIC command is rejected
with Check Condition status. The sense key is set to Illegal
Request (5h), and the ASC and ASCQ fields are set to 24h and
00h.
Byte 05, Bit 6 - VU (Vendor Unique)
There is no vendor unique definition for this bit.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
21-3
21 SEND DIAGNOSTIC (1Dh)