Fatal Load Error
Once the load process is started, it is irreversible. If a hardware or
power failure occurs during the load operation, the CTS may not be
able to operate. In this event, you can use the CTS Monitor program
to reload the microcode through the Monitor port (refer to the
documentation for CTS Monitor ).
Aborted Command
If you issue a command other than WRITE BUFFER, INQUIRY, or
REQUEST SENSE to the CTS during a WRITE BUFFER command
sequence, the CTS terminates the command with Check Condition
status. The sense key is set to Aborted Command (Bh), and the ASC
and ASCQ are set to 00h. The Fault Symptom Code is set to EBh.
Illegal Request
If you have not enabled the CTS to disconnect from the SCSI bus
during the WRITE BUFFER operation, the CTS returns Check
Condition status with the sense key set to Illegal Request (5h).
26-6
EXB-8205 and EXB-8505
(Standard and XL)
510503
26 WRITE BUFFER (3Bh)