Setmark Detected (EXB-8505 Only)
Note: This error applies to tapes written in 8500c format only.
If the RSmk bit in the MODE SELECT Device Configuration page
(Page Code=10h) is set to 1 and the EXB-8505 detects a setmark before
completing the read operation, the EXB-8505 returns Check Condition
status. The REQUEST SENSE data is set as follows:
Valid 1
Filemark 1
Sense Key No Sense (0h)
Information
bytes
Depend on the setting of the Fixed bit, as follows:
If the Fixed bit is 0, equal the requested transfer length
If the Fixed bit is 1, equal the difference between the
requested transfer length and the actual number of
logical blocks read.
ASC 00h
ASCQ 03h
FSC 1Dh
When the READ command terminates, the logical position is at the
EOT side of the setmark encountered.