9.5 Log Parameter Data Blocks
(Page Codes=02h and 03h)
When the Page Code is 02h or 03h, the CTS returns information about
its log parameters (counters) immediately after it returns the
Parameter List Header. For each counter, the CTS returns a data block
that includes four bytes of descriptive information and a
variable-length parameter value. The total number of bytes returned
for each counter is equal to the value for the Parameter Length field
plus four.
The CTS returns the log parameter data blocks for the specified LOG
SENSE page in Parameter Code order (unsigned). The code for the
first counter will be equal to or greater than the value you specified
for the Parameter Pointer field in the CDB.
Bit
Byte
76543210
00 (MSB)
Parameter Code
01 (LSB)
02 DU DS TSD ETC TMC RSVD LP
03 Parameter Length
04 (MSB)
Parameter Value
…
nn
(LSB)
Bytes 00 and 01 – Parameter Code
The Parameter Code field identifies the code of the counter for which
the CTS is returning a value, as follows:
0002h – Total Rewrites or Total Rereads, depending on the Page Code
0003h – Total Errors Corrected
0004h – Total Times Errors Processed
0005h – Total Bytes Processed
0006h – Total Unrecoverable Errors
These counters are described in Table 9-1 and Table 9-2.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
9-7
9 LOG SENSE (4Dh)