Write Error Counters Page (Page Code=02h)
When you specify 02h for the Page Code, the CTS returns information
about the counters listed in Table 9-1.
Parameter
Code
Counter Name
Parameter
Length
(bytes)
Default
Cumulative
Value
Default
Threshold
Value
0002h
Total Rewrites
3 0 all FFs
0003h
Total Errors Corrected
3 0 all FFs
0004h
Total Times Errors Processed
3 0 all FFs
0005h
Total Bytes Processed
5 0 all FFs
0006h
Total Unrecoverable Errors
2 0 all FFs
Total Rewrites
The Total Rewrites counter indicates the number of physical blocks
the CTS rewrote to the tape because of errors detected during
read-after-write operations. Only user data blocks and short filemark
blocks are ever rewritten.
Note: The Total Rewrites counter is equivalent to the Total Errors
Corrected counter. Thresholds, threshold criteria, and
cumulative values always use these counters and reflect the
last set value.
Total Errors Corrected
The Total Errors Corrected counter contains the same value as the
Total Rewrites counter.
Total Times Errors Processed
The Total Times Errors Processed counter contains 0 since this is only
a read function (write errors are rewritten). The default value is 0 and
will never change.