Data Cartridge Not Present before Reset
When a data cartridge is not present, the CTS responds to the reset as
follows:
It returns Check Condition status to the first command received.
The sense key is set to Unit Attention (6h), and the ASC and
ASCQ fields indicate that a reset occurred.
It processes all non-motion commands. The TEST UNIT READY
(00h) command returns Check Condition status with the sense
key set to Not Ready (2h). The ASC and ASCQ fields indicate that
no tape is present.
It returns Check Condition status to all tape motion commands.
The sense key is set to Not Ready (2h), and the ASC and ASCQ
fields indicate that no tape is present.
Note: After a reset, wait until the green LED turns off before
inserting a data cartridge into the CTS.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
3-37