Using the Motion Threshold and Reconnect Threshold
This section explains how to increase the efficiency of data transfers to
and from the CTS’s buffer by adjusting the motion threshold and
reconnect threshold. Although start/stop operations are not as efficient
as streaming operations, you can maximize start/stop performance
by adjusting the motion threshold. You can maximize streaming
performance by adjusting the reconnect threshold. You adjust these
thresholds using the MODE SELECT command (see Table 3-5), or you
can request default values for these thresholds as an EEPROM option.
Table 3-5 indicates where you can set the motion and reconnect
thresholds using the MODE SELECT command. If you send
conflicting values on different pages of the MODE SELECT
command, the value that is received last by the CTS takes precedence.
To set this
threshold...
Use any of these fields in the MODE SELECT command...
Page Field
Motion
threshold
(Non-page format)
Motion Threshold—Byte 02 of the
vendor-unique parameters
Device Configuration Page
(Page Code = 10h)
Write Buffer Full Ratio—Byte 04
and
Read Buffer Empty Ratio—Byte 05
(these values must be equal)
Vendor Unique Parameters Page 1
(Page Code = 20h)
Motion Threshold—Byte 04
Reconnect
threshold
(Non-page format)
Reconnect Threshold—Byte 03 of
the vendor-unique parameters
Disconnect-Reconnect Page
(Page Code = 02h)
Buffer Full Ratio—Byte 02
and
Buffer Empty Ratio—Byte 03
(these values must be equal)
Table 3-5 Where to set the motion threshold and reconnect threshold