Autosizing of Data Cartridges
Autosizing is the process that occurs during a load operation when
the CTS spaces forward from the physical beginning of tape (PBOT)
to the logical beginning of tape (LBOT) and determines the length of
thetapeinuse.
The CTS accurately determines the length of the EXATAPE 15m, 54m,
and 160m XL cartridges during the load operation. For the EXATAPE
112m cartridge, the CTS initially uses the settings of the CT and 112m
bits in the MODE SELECT command (see page 10-21) to estimate the
length of the tape. Then, the CTS resizes the 112m cartridge as the
tape position approaches LEOT.
The CTS estimates the tape length as shown in Table C-4.
Type of EXATAPE
loaded
Setting of
CT bit
Setting of
112m bit
Tape initially
sized as...
15m or 54m
00
15mor54m
10
0or1 1
112m
00
106m tape
a
10
0 or 1 1 112m
160m XL
b
0or1 0or1 160m
a
Exabyte does not recommend using tapes of this length in the CTS.
b
This tape size is intended for the EXB-8505XL and EXB-8205XL only.
If the CT and 112m bits are incorrectly set for the type of cartridge
loaded, the CTS may increase the estimated block count when it
resizes the tape. This ensures that LEOT is always detected correctly
and prevents tape capacity errors.