10.15 Vendor Unique Parameters Page 2
(Page Code=21h)
Bit
Byte
76543210
00 Reserved Page Code
01 Page Length
02 Reserved
03 Reserved LPART WWR
04
Reserved
05
Byte 00, Bits 5 through 0 - Page Code
The Page Code identifies the page being transferred. The valid value
is 21h (Vendor Unique Parameters Page 2).
Byte 01 - Page Length
The Page Length indicates the number of bytes in the Vendor Unique
Parameters Page 2 that follow this byte. The valid value is 04h.
Byte 03, Bit 1 - LPART (Load Partition)
EXB-8505 The LPART bit indicates which partition you want the EXB-8505 to
position the tape to the next time it loads a tape or after it formats two
partitions on the current tape (8500c format only). The values for this
bit are as follows:
0 – For a dual-partition tape, position to the beginning of the second
partition on the tape.
Note: This is the default position immediately after a
dual-partition tape is loaded or a tape is formatted with
two partitions. You can change the default through an
EEPROM option (see the “Load to partition” option on
page A-9).
1 – For a dual-partition tape, position to the beginning of the first
partition on the tape (LBOT).
10-56
EXB-8205 and EXB-8505
(Standard and XL)
510503
10 MODE SELECT (15h) and MODE SENSE (1Ah)