Exabyte EXB-8205 Instruções de Operação Página 216

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 446
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 215
10.17 Exceptions and Error Conditions
The following exceptions and error conditions can occur with the
MODE SELECT command.
Illegal Value in MODE SELECT Data
If one of the bytes sent with the MODE SELECT data contains an
illegal value or if a reserved bit is set, the CTS returns Check
Condition status. To determine which byte contains the error, issue a
REQUEST SENSE command. The sense key will be set to Illegal
Request (5h) and the Fault Symptom Code field (byte 28) will indicate
which of the consecutively received bytes is in error. For example, if
the Block Descriptor Length field (byte 03) in the Parameter List
Header is invalid, the value for the Fault Symptom Code byte would
be 04h.
Note: The CTS counts the first byte received as byte 1, not as byte 0.
10-60
EXB-8205 and EXB-8505
(Standard and XL)
510503
10 MODE SELECT (15h) and MODE SENSE (1Ah)