Exabyte EXB-8205 Instruções de Operação Página 282

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 446
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 281
21.1 About This Command
The SEND DIAGNOSTIC command causes the CTS to perform
certain self-diagnostic tests. If a test is successful, the CTS returns
Good status; otherwise, it returns Check Condition status. When this
command is followed by a RECEIVE DIAGNOSTIC RESULTS (1Ch)
command or a REQUEST SENSE (03h) command, detailed results of
these diagnostic tests are reported to the initiator.
Notes:
To ensure that the diagnostic data returned is valid, the SEND
DIAGNOSTIC command must be immediately followed by the
RECEIVE DIAGNOSTIC RESULTS command.
To ensure that the results of the diagnostic test are not destroyed
by a command sent by another initiator, the CTS should be
reserved for the initiator’s exclusive use.
The initiator must support the disconnect option if you plan to
usetheSENDDIAGNOSTICcommandbecausetheCTSwill
disconnect from the initiator while the command is executing.
If the requested test involves a tape, the SEND DIAGNOSTIC
command returns Check Condition status with the sense key set
to Illegal Request (5h) and the ASC and ASCQ fields set to 53h
and 02h under either of the following conditions:
The Prevent bit in the PREVENT/ALLOW MEDIUM
REMOVAL (1Eh) command is set to 1 (prevent media
removal).
The NAL bit in MODE SELECT (15h) is set to 0 (autoloading
disabled).
21-2
EXB-8205 and EXB-8505
(Standard and XL)
510503
21 SEND DIAGNOSTIC (1Dh)
Vista de página 281
1 2 ... 277 278 279 280 281 282 283 284 285 286 287 ... 445 446