9.1 About This Command
The LOG SENSE command enables you to retrieve statistical
information about the CTS’s read and write error recovery operations.
The CTS maintains this information in the following counters, which
are described in Table 9-1 and Table 9-2:
Total Number of Rewrites
Total Number of Rereads
Total Errors Corrected
Total Times Errors Processed
Total Bytes Processed
Total Unrecoverable Errors
Note: You can use the LOG SELECT (4Ch) command to specify
cumulative and threshold values for these counters. Refer to
Chapter 8 for more information.
As described in this chapter, the LOG SENSE data returned by the
CTS consists of a four-byte Parameter List Header and a log page.
Each log page contains zero or more log parameter data blocks, which
provide information about the counters.
9.2 Field Definitions
Byte 01, Bits 4 through 2 – Reserved
These bits are reserved.
Byte 01, Bit 1 – PPC (Parameter Pointer Control)
The PPC bit specifies what type of parameters you are requesting
from the CTS. This bit must be 0, which indicates that the CTS should
return all parameters for the selected log page, beginning with the
code in the Parameter Pointer field (bytes 05 and 06).
Byte 01, Bit 0 – SP (Save Parameters)
The CTS does not support the save parameters function. The valid
value for this bit is 0.
9-2
EXB-8205 and EXB-8505
(Standard and XL)
510503
9 LOG SENSE (4Dh)