FSC
Sense
Key
ASC ASCQ Description
CAh 6h 5Bh 01h
Unit Attention. Threshold met. (For
additional information about this error,
look at the Log Parameter Page Code
and Log Parameter Code bytes in the
REQUEST SENSE data.)
CBh 6h 2Ah 02h
Unit Attention. Log parameter changed.
ECh 1h 5Bh 02h
Recovered Error. Log parameter
overflow (a cumulative counter reached
its maximum value of all FFs). When this
occurs, the counter stays at its maximum,
the DU bit is set to 1 to disable updates,
and the CTS returns this Fault Symptom
Code.
This Fault Symptom Code indicates that
the CTS completed the command with no
error. Check Condition status is returned
only to alert the initiator that a counter
reached its maximum.
Table 8-4 REQUEST SENSE data for LOG SELECT errors and exceptions
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
8-13
8 LOG SELECT (4Ch)