Compression Errors
If you are writing in compressed format and the decompressed data
does not match the compressed data during the Compression
Integrity Check, the CTS aborts the data transfer. The data block
containing the compression error is not written to tape.
After aborting the data transfer, the CTS sends Check Condition
status to the initiator, followed by a Command Complete message.
The sense key is set to Aborted Command (Bh), and the ASC and
ASCQ are set to 10h and 00h.
You may be able to recover from this unlikely error by performing the
following actions:
If you are attempting to write a variable-length block, reissue
the WRITE command an unlimited number of times. Each time a
failure is detected, the CTS returns Check Condition status.
If you are attempting to write fixed-length blocks, follow these
steps:
1. Issue a REQUEST SENSE command.
2. Look at the Information Bytes to determine how many fixed
blocks need to be re-sent. These bytes indicate how many
logical blocks were not transferred successfully (including
the logical block with the compression error).
3. Adjust the initiator’s data pointer to reflect the number of
blocks that were successfully transferred.
4. Issue a WRITE command to re-send the blocks that were not
successfully transferred.
25-12
EXB-8205 and EXB-8505
(Standard and XL)
510503
25 WRITE (0Ah)