Sense Key = 4h (Hardware Error)
ASC
(Byte 12)
ASCQ
(Byte 13)
Explanation Related FSC
00h 00h
Undetermined hardware error.
58h, 5Ah, 67h, 68h, 6Dh,
FAh, FCh, FDh
08h 01h Logical unit communication timeout. 9Ah, 9Ch, ABh
08h 02h Logical unit communication parity error. A4h, A5h, A7h, A8h
0Ch 00h Hardware failure—Head sync error during write. A1h
11h 00h
A hardware error was detected during a read
operation.
17h, 18h
11h 02h Read decompression CRC failed. 19h
15h 01h Servo hardware failure. ADh
40h 80h
Controller hardware failure.
8Dh
44h 00h Internal software failure. 8Ch, 98h, 99h, A2h, ACh
Sense Key = 5h (Illegal Request)
ASC
(Byte 12)
ASCQ
(Byte 13)
Explanation Related FSC
00h 05h
TheCTSwasinwritemodeandaREADor
VERIFY command was issued.
0Eh
1Ah 00h Illegal transfer length in the CDB. CCh, D4h
20h 00h Illegal operation code. CDh
21h 00h
Logical block out of range.
D9h
24h 00h Invalid field in the CDB. CEh
25h 00h Logical unit not supported. CFh, D1h
26h 00h Invalid field in parameter list. D0h, EAh
27h 00h The data cartridge is write protected. 73h
30h 02h
The tape format is incompatible with the
command (for example, you are attempting to
write setmarks in a tape format that doesn’t
support setmarks).
D7h
Table E-5 REQUEST SENSE information for Sense Key 4h
Table E-6 REQUEST SENSE information for Sense Key 5h
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
E-5
Appendix E Error Information