Parameter
Code
Counter Name Description
0002h
Total Rewrites
WriteErrorCounterPage. Contains the number of physical
blocks the CTS rewrote to the tape because of errors detected
during read-after-write operations. Only user data blocks and short
filemark blocks are ever rewritten.
Note: This counter is equivalent to the Total Errors Corrected
counter. Thresholds, threshold criteria, and cumulative values
always use these counters and reflect the last set value.
Total Rereads
Read Error Counter Page. Contains the number of times the CTS
moved the tape backward to reread a portion of tape because a
block was missed.
0003h
Total Errors
Corrected
WriteErrorCounterPage. Contains the same value as the Total
Rewrites counter.
Read Error Counter Page. Contains the total number of blocks
the CTS recovered either by using the ECC algorithm or by
successfully rereading the block.
0004h
Total Times
Errors Processed
WriteErrorCounterPage. Contains 0 since this is only a read
function (write errors are rewritten). The default value is 0 and will
never change.
Read Error Counter Page. Contains the number of blocks the
CTS recovered by using the ECC algorithm.
0005h
Total Bytes
Processed
WriteErrorCounterPage. Contains the number of bytes
successfully written to the tape. This counter only includes user
data bytes, the gap bytes in user data blocks, and the bytes in
short filemark blocks. Rewritten data is not counted.
Read Error Counter Page. Contains the number of user data
bytes transferred to the initiator. Rewritten data is not counted.
0006h
Total
Unrecoverable
Errors
WriteErrorCounterPage. Contains the number of times the CTS
could not write a block to the tape.
Read Error Counter Page. Contains the number of blocks the
CTS could not read after exhausting all retries.
Table 8-2 Parameter Codes for LOG SELECT command