10.7 Vendor-Unique Parameters
(Non-Page Format)
Bit
Byte
76543210
00 CT RSVD ND RSVD NBE EBD PE NAL
01 Reserved 112m
02 Motion Threshold
03 Reconnect Threshold
04 Gap Threshold
Byte 00, Bit 7 - CT (Cartridge Type)
The CT bit works in conjunction with the 112m bit (byte 01, bit 0) to
indicate the size of the data cartridge that is expected to be loaded in
the CTS. Table 10-10 shows the combinations of settings for the CT
and 112m bits.
CT
bit
112m
bit
Size of cartridge expected
Notes
15m 54m 112m
00
✔✔
Use this setting for 15m and 54m tapes.
10 ?
Use this setting for unknown tape sizes.
0or1 1
Use this setting for 112m tapes. (When set to 1,
the 112m bit overrides the CT bit.)
Notes:
If you are using 160m XL data cartridges with an EXB-8505XL or
EXB-8205XL, the CTS ignores the settings of the CT and 112m bits.
You can set the CT bit only when the tape is positioned at LBOT.
Table 10-10 Settings for the CT and 112m bits
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
10-21