Message Processing in the Message Out Phase
Figure D-2 shows the message sequences for Message Out bytes
received during a previously initiated Message Out phase. Note that
Message Reject and Initiator Detected Error messages received after a
previous Message Out phase are treated as catastrophic errors
committed by the initiator.
Parity Error in the Message Out Phase
When parity checking is enabled and the CTS detects a parity error in
a message received from the initiator, the CTS requests that the
initiator reissue the message by going to the Message Out phase again.
If a parity error occurs during the first message sequence (Identify
message followed by contiguous Message Out bytes), the entire
sequence must be retransmitted (that is, the initiator should reissue
the Identify message and all following bytes). If a parity error is
detected the second time the message is received, the CTS goes to the
Bus Free phase by releasing the BSY signal.
D-6
EXB-8205 and EXB-8505
(Standard and XL)
510503
Appendix D SCSI Bus Message Processing and Error Recovery