Save Data Pointer (02h)
The CTS sends the Save Data Pointer message to direct the initiator to
save a copy of its present active data pointer for the CTS.
Restore Pointers (03h)
The CTS sends the Restore Pointers message to direct the initiator to
restore the most recently saved data pointers for the currently
attached LUN to the active state. Pointers to the Command, Data, and
Status locations for the LUN are restored to the active pointers.
Command and Status pointers are restored at the beginning of the
present command and status areas. The data pointer is restored to the
value at the beginning of the data area or the most recent Save Data
Pointer value.
Disconnect (04h)
The CTS sends the Disconnect message to inform the initiator that the
present physical path will be broken (the CTS will disconnect by
releasing the BSY signal) and that a later reconnect is required to
complete the current operation. If the disconnect privilege has been
granted by the initiator, the CTS can send this message at any time
after receiving the CDB (except as restricted by the ND bit of the
MODE SELECT command).
If the CTS does not send either the Disconnect message or the
Command Complete message before going to the Bus Free phase
(other than as a result of the reset condition), one of the following
situations has occurred:
A catastrophic error condition has occurred for the current
command
The initiator aborted the command
Note: The Disconnect message should not cause the initiator to save
the data pointer.