10.3 Field Definitions for MODE SENSE CDB
Byte 01, Bit 3 - DBD (Disable Block Descriptor)
The Disable Block Descriptor bit indicates whether the initiator wants
the 8-byte Block Descriptor returned as part of the MODE SENSE
parameter data. This bit is defined as follows:
0 – Send the Block Descriptor
1 – Do not send the Block Descriptor
Note: TheDBDbitmustbe0ifthePageCodeis0(non-page
format). Otherwise, the CTS returns Check Condition status
with a sense key of Illegal Request (5h). When the Page Code
is 0, use the Allocation Length field in the CDB to specify
whether the Block Descriptor is returned (see Table 10-5).
Byte 02, Bits 7 and 6 - PC (Page Control)
The Page Control field indicates the type of MODE SENSE parameter
data to be returned. The CTS supports the following values:
00h – Return current values. These are the parameters set by the last
successful MODE SELECT command, or the power-on default
values if a MODE SELECT command has not been executed
since the last power-on reset, SCSI bus reset, or Bus Device
Reset message.
01h – Return changeable values. All values that are changeable are
indicatedby1sineachbitofthechangeablefield.
Note: This field is used only for page format and must be 00h for
non-page format.
Byte 02, Bits 5 through 0 - Page Code
The Page Code field indicates which MODE SENSE parameter page
or pages the initiator is requesting. A value of 0 for this field indicates
that the parameters will be returned in non-page format.
Table 10-4 lists the values supported by the CTS for the Page Code
field.