16.2 Field Definitions
Bytes 03 and 04 - Allocation Length
The Allocation Length field specifies the number of bytes that the
initiator has allocated for the return of RECEIVE DIAGNOSTICS
RESULTS data.
If you are using the command to obtain diagnostic data, the
number of bytes of diagnostic data available from the CTS
dependsonthetypeofSENDDIAGNOSTICtestthatwas
performed (see Section 16.3 for more information).
To receive all available diagnostic information, specify a value for
the Allocation Length field that equals the Page Length for the
diagnostic page requested plus 4 bytes. A value of 0 for the
Allocation Length field indicates that no diagnostic data will be
returned and is not an error.
or
If you are requesting a trace of SCSI and servo activity, specify
500h for the Allocation Length field.
The CTS terminates the Data In phase when the number of bytes
specified in the Allocation Length field has been transferred or when
all available data has been transferred to the initiator, whichever is
less.
Byte 05, Bit 7 - TD (Trace Dump)
This bit indicates whether you are requesting diagnostic data or a
trace dump, as follows:
0 – Return diagnostic data (see Section 16.3 for more information).
1 – Return a trace of SCSI and servo activity (see Section 16.5 for more
information).
Byte 05, Bit 6 - VU (Vendor Unique)
There is no vendor unique definition for this bit.
May 1994 EXB-8205 and EXB-8505