Exabyte EXB-8205 Instruções de Operação Página 410

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 446
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 409
Message Processing in Message In Phase (Command
Complete)
Figure D-12 shows how messages are processed while the CTS is
attempting to send the Command Complete message.
Parity Error Sending the Command Complete Message In
If the initiator detects a parity error during the Command Complete
Message In phase, it sends a Message Parity Error message to the
CTS. The CTS responds by re-sending the Command Complete
message.
The initiator should count Message Parity Error messages to qualify
the communication. If the count exceeds some threshold, the initiator
should clear the CTS from the bus by doing one of the following:
Sending the Abort message
Performing a SCSI bus reset
Sending the Bus Device Reset message
Initial Phase:Message In
(C
o mma n d
C
omplete
)
Transition to: Message Out
Setsensekeyto
AbortedCommand(Bh)
Go BusFree
Reset
Go BusFree
Executewarmreset
Send Command
Completeagain
Go BusFree
Go BusFree
Abort
Message Parity
Error
All others
Figure D-12 Message processing during Command Complete Message In phase
D-24
EXB-8205 and EXB-8505
(Standard and XL)
510503
Appendix D SCSI Bus Message Processing and Error Recovery