Vista de página 353
EEPROM
option
Definition Possible values Default
value
Option
is set
to...
SEND
DIAGNOSTIC
special
operation
Controls the reporting of
an error if a tape is present
in the CTS during Test 100
of the SEND
DIAGNOSTIC (1Dh)
command. Also enables
you to convert the SEND
DIAGNOSTIC command to
ano-op.
See Chapter 21 for more
information.
NORMAL – The SEND DIAGNOSTIC
command works as determined by the
SEND DIAGNOSTIC command option
(see the previous option). If you select
Test 100 and a tape is present, the test
executes as if no tape were present.
The CTS never reports a tape-present
error (FSC=D5h) for Test 100.
NO TAPE – The SEND DIAGNOSTIC
command works as determined by the
SEND DIAGNOSTIC command option
(see the previous option). If you select
Test 100 and a tape is present, the
CTS reports a tape-present error
(FSC=D5h).
NO-OP – The CTS treats the SEND
DIAGNOSTIC command as a no-op
with no parameter checking.
SUBSET IF TAPE PRESENT –The
SEND DIAGNOSTIC command works
as determined by the SEND
DIAGNOSTIC command option (see
the previous option). If you select Test
100 and no tape is present, the test
works as defined in Chapter 21. If you
select Test 100 and a tape is present,
the CTS performs a subset of the
power-on self-test. This subset does
not affect the MODE SELECT data or
the tape position.
NORMAL
Perform
high-speed
search in
send
diagnostics
Allows or prevents
high-speed searches
during send diagnostics
operations (Tests 101 and
111 only).
NO – The CTS will never perform
high-speed searches during send
diagnostics operations.
YES – The CTS will perform a
high-speed search to EOT at the
beginning of send diagnostics
operations.
NO
Double the
read/write
passes in
send
diagnostics
Controls the number of
read/write passes
performed during send
diagnostics operations
(Tests 101 and 111 only).
NO – Two read/write passes are
performed.
YES – Double the number of read/write
passes performed (from two to four).
NO