Message Processing during Disconnect Sequence
Figure D-14 shows how messages are processed while the CTS is
executing the “disconnect” sequence. Note that attempts to change
the physical path characteristics are not allowed. Also, the disconnect
sequence may be aborted if the initiator sends a Message Reject
message.
Parity Error Sending Disconnect or Save Data Pointers
Message In
If the initiator detects a parity error when the CTS sends a Disconnect
or Save Data Pointers message in, it responds by sending a Message
Parity Error message to the CTS. The CTS responds by re-sending the
Disconnect or Save Data Pointers message.
The initiator should count Message Parity Error messages to qualify
the communication. If the count exceeds some threshold, the initiator
should clear the CTS from the bus by doing one of the following:
Sending the Abort message
Performing a SCSI bus reset
Sending the Bus Device Reset message
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
D-27
Appendix D SCSI Bus Message Processing and Error Recovery